Level 2 · Advanced Technician · Module 18
Dump Hoists
Safety arm use, operation and lubrication.
Lessons
- 01Using the Safety ArmUnloaded bodies only.
- 02Operation & LubricationDon't shock the body.
- 03Interpreting Hoist Capacity ChartsSelect a capacity entry by matching the hoist, body length, overhang and dump angle while retaining the chart's application assumptions.
- 04Safe Diagnostic SequencingBegin troubleshooting with hydraulic safety, circuit understanding and electrical checks before pursuing hydraulic faults.
- 05Tracing Power-Up, Gravity-Down OperationTrace the separate electrical and fluid paths used to extend and retract a gravity-down cylinder.
- 06Tracing Power-Up, Power-Down OperationRelate the powered-down circuit's coil commands, cylinder ports, return paths and relief protection.
- 07Diagnosing Voltage, Ground and Cable ProblemsConnect low-voltage symptoms to charging, grounding, connections and cable selection before condemning hydraulic components.
- 08Separating Relief, Check and Lowering-Valve FaultsDistinguish pressure protection, backflow prevention and commanded release by understanding each valve's function and failure modes.
- 09Diagnosing Directional and Load-Holding ValvesEvaluate directional-valve shifting and distinguish its faults from problems in the documented load-holding arrangement.
- 10Advanced Symptom-Based Fault IsolationUse motor behavior, cylinder direction and reservoir symptoms to select the documented diagnostic branch.