TrailerPro Academy
← Hydraulic Power Units & Remotes
LESSON 2 OF 12

Power-Up/Gravity-Down vs Power-Up/Power-Down

YOU WILL BE ABLE TO
  • Differentiate between Circuit 103 single-acting and Circuit 111 double-acting hydraulic power unit operations.
  • Identify remote control wiring color codes for blue, red, green, and white conductors.
  • Locate and verify primary and secondary relief valve factory settings on double-acting units.
TOOLS AT THE BAY
  • Digital Multimeter — Check for power at the start solenoid, motor, and solenoid coils during operation.
  • Wire Strippers — Prepare remote wiring leads (blue, red, green, or white) for terminal connection.

Circuit 103 (single acting): UP powers start solenoid and motor; fluid goes through the check valve out the P port. DOWN energizes the normally closed 2-way coil to return fluid to tank.

Circuit 111 (double acting): UP powers the motor and the round 4-way coil; DOWN powers the motor and the square coil on the load-holding valve.

Primary relief is factory set at 3200 psi; the 2nd relief on double-acting units is 1500 psi.

Remote wiring: UP = blue or red, DOWN = green, COMMON = white.

How It Works

Circuit 103 Single-Acting Operation

In a Power-Up/Gravity-Down configuration, the UP function powers the start solenoid and motor, sending fluid through the check valve via the P port. The DOWN function does not use the motor; it energizes a normally closed 2-way coil to allow fluid to return to the tank.

Circuit 111 Double-Acting Operation

A Power-Up/Power-Down configuration requires motor operation for both directions. The UP function powers the motor and the round 4-way coil. The DOWN function powers the motor and the square coil located on the load-holding valve.

Relief Valve Specifications

Standard units feature a primary relief valve factory set at 3200 psi. On double-acting units, a 2nd relief valve is present and set at 1500 psi. These settings are factory established and critical for safe operation.

⚠ CAUTION Never adjust relief valves without factory approval. Tampering voids warranty and can cause injury or death.

Diagnostic Chart

SymptomCheckSpec / ExpectedLikely cause & fix
Circuit 103 fails to lift but motor runs.Inspect fluid flow through the check valve and out of the P port.3200 psiPrimary relief valve may be bypassing fluid or check valve is stuck.
Basis: KTI DC Power Unit Troubleshooting Guide (Jan 2019)
Circuit 103 fails to lower.Check for power and activation of the normally closed 2-way coil.Per the applicable manualThe 2-way coil is not energizing to allow fluid return to the tank.
Basis: KTI DC Power Unit Troubleshooting Guide (Jan 2019)
Circuit 111 fails in the DOWN direction.Check for power at the motor and the square coil on the load-holding valve.1500 psiFailure of the motor to run or the square coil to energize prevents downward power.
Basis: KTI DC Power Unit Troubleshooting Guide (Jan 2019)
Circuit 111 fails in the UP direction.Check for power at the motor and the round 4-way coil.3200 psiFailure of the motor to run or the round 4-way coil to energize prevents upward power.
Basis: KTI DC Power Unit Troubleshooting Guide (Jan 2019)

At the Bay: Diagnose the Case

CASE 1 / 4

Circuit 103 fails to lift but motor runs.

  1. Test
  2. Compare
  3. Correct

Select the next check

Basis: KTI DC Power Unit Troubleshooting Guide (Jan 2019). A likely cause is a hypothesis; confirm it with the applicable service procedure before repair.

Common Bay Mistakes

  • ✕ Adjusting relief valves without factory approval.
  • ✕ Mistaking the square coil for the round 4-way coil on Circuit 111.
  • ✕ Assuming the motor should run during the DOWN function on a Circuit 103 unit.
  • ✕ Connecting the green wire to the UP function instead of DOWN.
  • ✕ Tampering with relief valves and voiding the warranty.
  • ✕ Confusing the 3200 psi primary relief with the 1500 psi secondary relief.

Quick Check

Practice only — not scored.

What components are energized when the UP button is pressed on a Circuit 111 unit?
Which wire color is used for the COMMON connection in the remote wiring?
The bay reports: Circuit 103 fails to lift but motor runs. Which check addresses this condition?
Hands-on: Shop Test Equipment
SHOP TEST EQUIPMENT · SIMULATED READINGS

Hydraulic Pressure & Relief Gauge

0–5,000 psi gauge on the pump pressure port, DC clamp meter, battery voltmeter

🛠 Equip your bay for this test →

Symptom: Routine check before a customer pickup.

Pump pressure
0psi
Hold at full stroke to read relief
Battery voltage
12.7V
Motor current
0A
Bed drift (pump off)
0.0in/min
Load the bed to test
Spec limits used
  • 3,200 psi — Primary relief (factory preset) (KTI Hydraulics Troubleshooting Manual 2019)
  • 1,500 psi — Secondary relief, circuit 111 (KTI Hydraulics Troubleshooting Manual 2019)
  • below 9 V — Low-voltage alarm (KTI remote)
  • illustrative only — Motor current & voltage drop (General shop practice)
Your diagnosis

Simulated readings for practice. Always follow the manufacturer's procedure and values on a real trailer.

Source: KTI DC Power Unit Troubleshooting Guide (Jan 2019) — 5–11